Manpages

Manpage of sane-sm3600

sane-sm3600

Section: SANE Scanner Access Now Easy (5)
Updated: 10.02.2002
Index
Return to Main Contents
 

NAME

sane-sm3600 - SANE backend for Microtek scanners with M011 USB chip  

DESCRIPTION

The sane-sm3600 library implements a SANE (Scanner Access Now Easy) backend that provides access to some Microtek scanners with the Toshiba M011 custom USB chip. This backend should be considered alpha.

There exist a backends for Microtek scanners with SCSI command set. Refer to sane-microtek(5) and sane-microtek2(5) for details.

At present, the following scanners are known positively to work with this backend:

Vendor Product id: Remark:
-------- -------------- -----------
Microtek ScanMaker 3600 all modes ok
Microtek ScanMaker 3700 reported to work
Microtek ScanMaker 3750 reported to work

If you own a Microtek scanner with the M011 chip other than the ones listed above, it may or may not work with SANE!

 

FRONTEND OPTIONS

This backend dynamically enables the options for the frontend, that are supported by the scanner in dependence of the scanning-mode and other options. Not supported options are disabled.

The following options are supported by the Microtek2-driver:

Color, grayscale, halftone and lineart scans.

contrast, brightness, control, gamma correction.

 

DEVICE NAMES

This backend does not support device names in a standardized form.

 

CONFIGURATION

This backend does not support a configuration file right now.

 

FILES

/usr/lib/sane/libsane-sm3600.a
The static library implementing this backend.
/usr/lib/sane/libsane-sm3600.so
The shared library implementing this backend (present on systems that support dynamic loading).

 

PERMISSIONS AND INTERFACES

The backend uses libusb and it's pseudo files in /proc/bus/usb/*. Since libusb versions 0.1.3b and 0.1.4 have incompatible binary data structures, You must be shure not to have obsolete header files. When You mix wrong versions, the scanner detection code will raise a "segment violation".

These files are normally owned by root and You are responsible to get access to these files, for example chown-ing them to Yourself. If You have no right permissions, the backend will find the device, but You'll get an I/O error.

The better way is to use automatical hotplugging. See http://sm3600.sf.net/hotplug.html for instructions and useful links.

 

ENVIRONMENT

SANE_DEBUG_SM3600
If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend. E.g., a value of 128 requests all debug output to be printed. Smaller levels reduce verbosity. To see error messages on stderr set SANE_DEBUG_SM3600 to 1.


E.g. just say:
export SANE_DEBUG_SM3600=5

 

SEE ALSO

sane-microtek2(5), http://sm3600.sourceforge.net

 

AUTHOR


Marian Eichholz (eichholz@computer.org)
Glenn Ramsey (glenn@componic.com)


 

Index

NAME
DESCRIPTION
FRONTEND OPTIONS
DEVICE NAMES
CONFIGURATION
FILES
PERMISSIONS AND INTERFACES
ENVIRONMENT
SEE ALSO
AUTHOR

This document was created by man2html, using the manual pages.
Time: 07:20:45 GMT, April 25, 2024